NOTAS DE ENDODONCIA

APOYO ACADÉMICO POR ANTOLOGÍAS

UNIDAD 4:  INSTRUMENTAL ESPECIALIZADO PARA ENDODONCIA

Profesor:  Dr. Ricardo Rivas Muñoz

CONTENIDO GENERAL DEL CURSO CONTENIDO DE LA UNIDAD BIBLIOGRAFÍA ARTÍCULOS REVISADOS PALABRAS CLAVE SECCIÓN:                     6

1ª Sección de 6 que forman toda la Unidad de Instrumental

CONTENIDO DE LA UNIDAD 4:

4.1.Clasificación. Según la Organización Internacional para Normas (ISO) y Federación Dental Internacional (FDI)
4.1.1.Instrumentos únicamente de uso manual
4.1.2.Instrumentos movidos por torno y cabeza operatoria en dos piezas
4.1.3.Instrumentos movidos por torno, vástago y cabeza operatoria en una sola pieza
4.1.4.Conos para conductos

4.2.Clasificación según Grossman


4.3.Estandarización de los instrumentos endodónticos.
4.2.1.Requisitos de la estandarización
4.2.2.Dimensiones y colores estandarizados

4.4.Descripción de cada instrumento siguiendo la Clasificación de Grossman

4.3.1.Instrumentos de exploración
4.3.1.1.Características de cada instrumento
4.3.1.4.Modo de uso de cada instrumento

4.3.2.Instrumentos de extirpación
4.3.2.1.Características de cada instrumento
4.3.2.2.Modo de uso de cada instrumento

4.3.3.Instrumentos de ensanchado
4.3.3.1.Manuales

Instrumentos de níquel-titanio (NiTi)


4.3.3.2.Activados por torno automático (giratorios y rotatorios)
4.3.3.3.Características de cada instrumento
4.3.3.4.Modo de uso de cada instrumento

 

4.3.4.Instrumentos para obturación
4.3.4.1.Manuales

4.3.4.2.Activados por torno automático
4.3.4.3.Características de cada instrumento
4.3.4.4.Modo de uso de cada instrumento

 

PALABRAS CLAVE:

ampliación

conformación

debridación

ensanchadores

exploración

obturación

 

   

REGRESAR A: Activados por torno automático (giratorios y rotatorios)

 

RESUMEN DEL ARTÍCULO CITADO:

ABSTRACT

DEFECTS IN GT ROTARY INSTRUMENTS AFTER USE: AND SEM STUDY.

Teresa Roberta Tripi, DDS, Antonio Bonaccorso, dds, Valeria Tripa, DDS, Gulielmo guido Condorelli, DDS, and Ernesto Rapisarda,MD,DDS.

Use rotary ni-ti instruments require frequent replacement. This laboratory studty evaluated defectsof GT Rotary instruments  before and after usage. The instruments were fixed into  custom-made holders and photographed  in a sem at x260 to x12000 magnification at preset points. Instruments sizes with 1.0,0.8 and 0.6 taper and instrument sizes 35 with 1.2 taper were used in 12 canals.The used instruments were cleaned and then reexamined in a SEM as before. The precense of 11 types of conditions was scored from the pre and postusage photographs.

No instruments facturing or plastic deformation was observed during the test. The precence of debris, pitting and scraping changed significantly. Imperfections were found on used GTrotary instruments and the precense of defects (pitting, scraping, and bluntcutting edges) increased in all of the instruments. The behavior ofr GT rotary instruments with usage seems to be different, compared with that found in other instruments.

Tripi, T.R. et al. DEFECTS IN GT ROTARY INSTRUMENTS AFTER USE: AN SEM STUDY JOE  December 2001;27(12):782-785. Disponible en: http://www.jendodon.com/article/S0099-2399(05)61042-4/abstract Consultado el 10 abril 2008

Investigado por Gustavo Díaz Sánchez, Alumno del grupo 2601 (2008), FES Iztacala, UNAM

 